Home ProductsIonizing Air Blower

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room

China China Static Technology Online Marketplace certification
China China Static Technology Online Marketplace certification
Easy to talk with, very professional and fast service, the flag quality is super good. Even better than we ordered from Germany!!

—— Germany Fabian Scherb

I want to say that your products very good. Thank you for all your suggestion, also good after sales service.

—— Mr Abílio Cipriano

Excellent quality and fast delivery.

—— Victor

I'm Online Chat Now

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room
Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room

Large Image :  Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room

Product Details:

Place of Origin: China
Brand Name: AP&T
Certification: CE
Model Number: AP-DJ1802

Payment & Shipping Terms:

Minimum Order Quantity: 1 pcs
Price: negotiation
Packaging Details: Standard Export Packing (Carton)
Delivery Time: 3 to 5 working days
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 2000 pcs / month
Detailed Product Description
Discharge Speed: <2s Ion Balance: ±10V
Power: 12W Input Voltage: 220V/50HZ Or 110V/60HZ
Effective Range: 1200*600mm Dimension: 180*72*201.5mm
High Light:

ionized air blower

,

ionised air blower

LED Display Intelligent Control Ionizing Air Blower Auto-cleaning Desktop Ion Fan

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room 0Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room 1

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room 2

 

 

Industry Application

Electronics, Plastic ,Chemical ,Printing, Optics Industry

 

Specification

Model No AP-DJ1802
Input voltage DC 24V (dual RJ45 interface)
Input current <0.6A
Output voltage DC±5KV→±5.5KV
Power <14.5W
Ion emit DC
Emitter Tungsten
Discharge range 750*300mm(L*W)
Air volume <179CFM
Noise <75dBA(150mm from air outlet)
Ozone thickness ≤0.05ppm(150mm from air outlet)
Ion balance ≤|±10V|
Discharge speed ≤1.5S(300mm from air outlet)
Alarm indication

Boot instant-blue light

Normal working -Green light(Under monitoring)

Fan alarm -Red light flash with beeping

Ionization abnormal-Red light slow flash with beeping

Blue light blinks when infrared debugging

Working temperature 0℃-50℃
Working humidity <70%RH
Dimension 177*81*205.5mm(L*W*H)
Power adaptor

1. Interface power supply (default configuration):

INPUT: AC100—240V 50 / 60Hz;

OUTPUT: DC24V 2A (dual RJ45 interface)

2. Jack-type power supply (customized):

INPUT: AC100—240V 50 / 60Hz;

OUTPUT: DC24V 2A (5.5 * 2.5 single male head)

Integrated power supply

(Optional)

INPUT:AC100—250V 50/60Hz

OUTPUT: DC24V 2A (16 RJ45 interfaces)

Communication method RS485
Shell material Aluminum dusting
Installation accessories 1 pair of U-shaped aluminum powder spraying mounting bracket, 2 pairs of stainless steel screw handles (M5 × 8)
Weight Bare metal (including bracket) 1125g
Net weight (network cable, power cord, adapter, remote control) 1590g
Gross weight 2080g
Quality assurance 1Year
Certificate CE

Anti Static Equipment Desktop Ionizing Air Blower For Cleaning Room 3

Testing standard:ANSI/ESD.STM3.1,ANSI/ESD.SP3.3,SJ/T 11446—2013

Testing instrument:Trek157 Static tester

Testing voltage:±1000V → ±100VAttenuation

Testing environment :Humidity50±5%;Tempertaure:23±3℃

 

Notice on use and safety warning

 

  • Read this manual carefully before installing and using of the device.
  • Be sure the device reliable ground connected during use, otherwise may cause bar body burn..
  • Do not use this device in the environment where the humidity is greater than 75%.
  • Do not use this equipment in a flammable or explosive environment.
  • It is strictly forbidden to disassemble device without authorization. Internal maintenance and repair must be carried out by professionals.
  • Touch water is strictly forbidden, Otherwise will be electric shocked or fire.
  • Check or replace the product, you must turn off the power, otherwise it may cause electric shock or fire
  • The product is designed for static elimination. It is strictly forbidden to use for other purposes. Any abnormal use may cause machine malfunction, electric shock, fire and other hidden dangers.,
  • Do not touch the electrode needle when the power is on, otherwise it may cause malfunction and electric shock.
  • The emitter is a sharp metal object, please use it with care.
  • Before powering on the product, please check the specifications of the power supply. Any power supply that does not meet the specifications will cause damage or even failure
  • Please check the product power cord/communication line regularly. If it is damaged, please replace it immediately, otherwise it will cause problems such as leakage, poor communication and abnormal operation.

Contact Details
China Static Technology Online Marketplace
Send your inquiry directly to us (0 / 3000)