| Place of Origin: | China |
| Brand Name: | KRE |
| Minimum Order Quantity: | 1 set |
|---|---|
| Payment Terms: | TT or LC |
| Highlight: | energy meter calibration equipment |
||
|---|---|---|---|
Automatic 0.1 Accuracy Electric Energy Meter Calibration Of Single Phase Energy Meter
This is a no-Ioad on-site test bench for single phase energy meters integrated with reference meter and source.
Main features
1. Accuracy class:0.1
2. Simultaneous measurement for 1-3 static single phase energy meters
3. Measurement for single phase local prepayment smart energy meters and single phase remote prepayment smart energy meters
4. Automatic/manual measurement of creeping and starting (of energy meters )
5. Wide measuring range reference meter integrated
6. Proofreading of constant by measuring pulse number,time,and start-stop power value;dial measurement according to number of KWh,time and number of pulse;preset number of KWh,the dial will stop accordingly
7. Automatic measurement of register
8. GPS reference clock integrated,time pairing for energy meters
9. Individual voltage loop for each testing position
![]()
Technical data
|
General |
|
|
Power supply |
220V±30% |
|
Power consumption |
<300VA |
|
Ambient temperature |
-20℃~40℃ |
|
Relative humidity (not condensing) |
40%~95% |
|
Dimension(L×W×H, mm) |
400×320×160 |
|
Weight |
<10Kg |
|
Warm-up time |
10min |
|
MTBF (Mean Time Between Failures) |
≥50000hrs |
|
Life time of whole set |
≥10Yrs |
|
LCD color display |
8”, 800×600 TFT |
|
Communication port |
RS232, USB |
|
Output voltage |
|
|
Measuring range |
30V~240V |
|
Adjusting range |
30V~240V continue adjustment |
|
Adjusting fineness |
0.002% |
|
Distortion |
≤2% |
|
Capacity |
≥10VA/position |
|
Output current |
|
|
Measuring range |
0.01~80A |
|
Adjusting range |
0.01~80A continue adjustment |
|
Adjusting fineness |
0.002% |
|
Distortion |
≤2% |
|
Capacity |
≥70VA/position |
|
Starting output current |
10mA |
|
Output power |
|
|
Stability |
≤0.03%/2min |
|
Output phase |
|
|
Adjusting range |
0°~360° |
|
Adjusting fineness |
0.01° |
|
Output frequency |
|
|
Adjusting range |
45~65Hz |
|
Adjusting fineness |
0.01Hz |
|
Reference meter |
|
|
Accuracy class |
0.1(direct connection), 0.3 (connected via clamp-on CT’s) |
|
Testing positions |
1~3 |
|
Monitoring |
|
|
Voltage |
Accuracy: 0.1 6 digits displayed Resolution: 0.1% |
|
Current |
Accuracy: 0.1 6 digits displayed Resolution: 0.1% |
|
Phase |
Accuracy: 0.2° 6 digits displayed Resolution: 0.2° |
|
Frequency |
Accuracy: 0.01Hz 6 digits displayed Resolution: 0.01Hz |
|
Standard deviation estimates |
≤0.02% |
|
Phase differences |
Voltage: ≤0.3 Current: ≤0.3 |
|
Reference time standard |
Frequency: 1Hz, 500kHz (TTL level) Stability: 2×10-8/day Accuracy: 2×10-7 |
|
Insulated resistant |
Output voltage/current loops to enclosure:>10MW Output voltage loop to current loop:>10MW Current to enclosure:>10MW |
|
Withstand voltage |
Output voltage/current loops to enclosure: 2000V/min, 50Hz Output voltage loop to current loop: 2000V/min, 50Hz Current to enclosure: 2000V/min, 50Hz |
Contact Person: Mr. li
Tel: 66668888